Carbon Monoxide and Your Chimney: What Rochester Homeowners Must Know

A carbon monoxide detector sounding an alarmCO
Carbon monoxide is odorless: detectors on every floor are the only warning.

If your carbon monoxide alarm is sounding right now: get everyone out of the house immediately, call 911 from outside, and do not re-enter until emergency responders have cleared the building. CO is colorless, odorless, and can incapacitate before you feel seriously ill — never try to "find the source" while an alarm is active. Once the house is safe, the question becomes why it went off, and for Rochester homeowners, the chimney system is one of the first places to look.

Many homeowners asking "why does my CO detector go off?" assume the furnace is at fault. Sometimes it is. But the chimney and venting system — the path combustion gases take to leave your home — is just as often the problem, especially in Rochester's stock of 19th- and early-20th-century brick houses with older, sometimes unlined flues.

Key Takeaways

If Your CO Alarm Sounds: The Emergency Steps

This comes first because nothing else in this article matters if it's read during an active alarm. The sequence from fire-safety guidance is simple:

Never assume a sounding alarm is a false alarm or a dying battery. A low-battery chirp is a short, single beep every 30–60 seconds; an alarm is a loud, repeating pattern. If you can't tell the difference, treat it as an alarm.

How a Chimney Puts CO Into Your Home

Every fuel-burning appliance — furnace, boiler, water heater, fireplace, wood stove — produces carbon monoxide. In a healthy system, the chimney's draft carries all of it up and out. CO enters living space when that venting path fails, in one of three ways:

Appliance-side failures — a cracked heat exchanger, a misadjusted burner — also produce CO, which is why post-event diagnosis should cover both the appliances and the venting system, not one or the other.

Why Rochester Homes Are Especially at Risk

Three local realities stack the odds. First, the housing stock: neighborhoods like the 19th Ward, Corn Hill, Park Avenue, and Maplewood are dominated by brick homes built between the 1850s and 1930s. Many still vent through original clay-tile-lined flues — and some through flues with no liner at all. Second, the climate: lake-effect winters off Lake Ontario mean more than 100 freeze-thaw cycles in a bad year. Water enters mortar joints and liner cracks, freezes, expands, and widens them a little more each season. Third, the pattern of upgrades: Rochester's older homes have almost all been re-furnaced, re-windowed, and re-insulated at least once, and each project changed the house's air balance without anyone re-checking whether the chimney still drafts.

Multi-flue stacks add another wrinkle. A single chimney may carry the furnace flue, a fireplace flue, and an abandoned third run. A blockage or liner failure in one flue can affect the draft of its neighbor, and abandoned openings capped decades ago sometimes communicate with living space through gaps in the masonry.

What to Do After a CO Alarm Event

Once the fire department has cleared the house, treat the event as a diagnostic starting point rather than a scare that's over:

Frequently Asked Questions

Why does my CO detector keep going off if my furnace seems fine?

A furnace can burn cleanly while its exhaust still enters the house through a blocked flue, cracked liner, or backdrafting chimney. The appliance working "fine" rules out nothing — the venting path has to be checked too. Treat every alarm as real: get out, call 911, then have both the appliances and the chimney inspected.

Can a fireplace cause carbon monoxide poisoning?

Yes. A fireplace with a blocked flue, a closed or stuck damper, or negative pressure in a tightly sealed home can spill smoke and CO into the room. If smoke ever backs into the room when you burn, stop using the fireplace and have the chimney inspected before the next fire.

Where should CO detectors be placed in the house?

Follow the manufacturer's instructions, which generally call for a detector on every level of the home and one outside each sleeping area. Basements and bedrooms matter most — CO incidents often happen at night while the furnace runs. Replace detectors at the end of their rated service life, typically five to seven years.

Can weatherization really cause a CO problem?

Yes. Sealing drafts, adding insulation, and installing exhaust fans reduces the air available for combustion and can depressurize the house, pulling flue gases back down the chimney. If your CO issues started after an energy-efficiency upgrade, backdrafting is the first suspect — tell the inspector what changed and when.

What should I do before using my furnace or fireplace after a CO event?

Have the appliances checked by a licensed HVAC technician and the chimney inspected by a certified chimney sweep — ideally a Level 2 camera inspection, which is the standard after a venting malfunction. Don't relight anything until both are cleared in writing.

For service coverage across the city, visit the Rochester chimney services hub or browse the city-wide chimney FAQ. Neighborhood pages: 19th Ward, Corn Hill, and Maplewood. Continue reading: Smoke Backing Into Your Room: 5 Common Causes and What Is a Level 2 Chimney Inspection?.

Speak with a local chimney professional. Call today to schedule your chimney service.